Automatic Subroutines for Monitoring Conditions
Often it is desirable to monitor certain conditions continuously without tying up the host or SMC–4000
program sequences. The SMC–4000 can monitor several important conditions in the background. These
conditions include checking for the occurrence of a limit switch, a defined input, position error, or a
command error. Automatic monitoring is enabled by inserting a special, pre-defined label in the
applications program. The pre-defined labels are:
For example, the #POSERR subroutine will automatically be executed when any axis exceeds its position
error limit. The commands in the #POSERR subroutine could decode which axis is in error and take the
appropriate action. In another example, the #ININT label could be used to designate an input interrupt
subroutine. When the specified input occurs, the program will be executed automatically.
*Note An application program must be running for automatic monitoring to function.
Example - Limit Switch:
This program prints a message upon the occurrence of a limit switch. Note, for the #LIMSWI routine to
function, the SMC–4000 must be executing an applications program from memory. This can be a very
simple program that does nothing but loop on a statement, such as #LOOP;JP #LOOP;EN. Motion
commands, such as JG 5000 can still be sent from the PC even while the "dummy" applications program is
being executed.
Now, when a forward limit switch occurs on the X axis, the #LIMSWI subroutine will be executed.
*Note The RE command is used to return from the #LIMSWI subroutine.
*Note The #LIMSWI will continue to be executed until the limit switch is cleared (goes high).
Example - Position Error
#CMDERR
Bad command given
#ININT
Input specified by II goes low
#LIMSWI
Limit switch on any axis goes low
#MCTIME
Timeout for In-position trippoint, MC
#POSERR
Position error exceeds limit specified by ER
#TCPERR
Ethernet error
#LOOP
Dummy Program
JP #LOOP;EN
Jump to Loop
#LIMSWI
Limit Switch Label
MG "LIMIT OCCURRED"
Print Message
RE
Return to main program
:XQ #LOOP
Execute Dummy Program
:JG 5000
Jog
:BGX
Begin Motion
#LOOP
Dummy Program