Motion complete trippoint, Using an encoder with stepper motors – Yaskawa SMC–4000 User Manual
Page 302
![background image](https://www.manualsdir.com/files/819559/content/doc302.png)
292
SMC–4000 User Manual
Motion Complete Trippoint
When used is stepper mode, the MC command will hold up execution of the proceeding commands until
the controller has generated the same number of steps out of the step count register as specified in the
commanded position. The MC trippoint (Motion Complete) is generally more useful than AM trippoint
(After Motion) since the step pulses can be delayed from the commanded position due to stepper motor
smoothing.
Using an Encoder with Stepper Motors
An encoder may be used on a stepper motor to check the actual motor position with the commanded
position. If an encoder is used, it must be connected to the main encoder input.
NOTE: The auxiliary encoder is not available while operating with stepper motors. The position of the
encoder can be interrogated by using the command, TP. The position value can be defined by using the
command, DE.
NOTE: Closed loop operation with a stepper motor is not possible.
Command Summary - Stepper Motor Operation
Operand Summary - Stepper Motor Operation
Command
Description
DE
Define Encoder Position (When using an encoder)
DP
Define Reference Position and Step Count Register
IT
Motion Profile Smoothing - Independent Time Constant
KS
Stepper Motor Smoothing
MT
Motor Type (2, -2, 2.5, or -2.5 for stepper motors)
RP
Report Commanded Position
TD
Report number of step pulses generated by controller
TP
Tell Position of Encoder
Operand
Description
_DEa
Contains the value of the step count register for the “a” axis
_DPa
Contains the value of the main encoder for the “a” axis
_ITa
Contains the value of the Independent Time constant for the “a” axis
_KSa
Contains the value of the Stepper Motor Smoothing Constant for the “a” axis
_MTn
Contains the motor type value for the “a” axis
_RPn
Contains the commanded position generated by the profiler for the “a” axis
_TDa
Contains the value of the step count register for the “a” axis
_TPa
Contains the value of the main encoder for the “a” axis