Fl (forward limit), Setting – Yaskawa SMC–4000 User Manual
Page 123
113
SMC–4000 User Manual
FL (Forward Limit)
[Setting]
DESCRIPTION:
The FL command sets the forward software position limit. If this limit is exceeded during commanded
motion, the motor will decelerate to a stop. Forward motion beyond this limit is not permitted. The
forward limit is activated at position n + 1. The forward limit is disabled at position 2147483647. The units
are in counts.
When the reverse software limit is activated, the automatic subroutine
will be executed if it is
included in the program and the program is executing. See section on Automatic Subroutines.
ARGUMENTS: FL x, y, z, w or FLX=x or FL a, b, c, d
where
x, y z, w, or a, b, c, d are unsigned numbers
USAGE:
OPERAND USAGE:
_FLn contains the value of the forward software limit where n is an axis letter.
RELATED COMMANDS:
EXAMPLES:
While Moving
Yes
Minimum Value
-2147483648
In a Program
Yes
Maximum Value
+2147483647
Command Line
Yes
Default Value
2147483647
Can be Interrogated
Yes
Default Format
Position Format
Used as an Operand
Yes
Virtual Axis
No
#TEST
Test Program
AC 1000000
Acceleration Rate
DC 1000000
Deceleration Rate
FL 15000
Forward Limit
JG 5000
Jog Forward
BGX
Begin
AMX
After Motion
TPX
Tell Position
EN
End