Smc–4000 user manual – Yaskawa SMC–4000 User Manual
Page 261
251
SMC–4000 User Manual
SMC–4000 Command Interrogation List
Command
Definition
units
min
max
default
_AB
Status of abort input
status
0=Aborted
1=OK
n/a
_ACx
Axis acceleration rate
counts/sec2
1024
67107840
256000
_AEx
"Last absolute encoder read (0=X, 1=Y, etc)"
code
0
3
n/a
_ALx
High speed position capture status
status
0=TRIPPED
1=NOT YET
0
_AV
Distance from the start of vector sequence
counts
0
2147483647
0
_BGx
Is axis in motion?
status
0=NO
1=YES
0=NO
_BK
The program debug breakpoint
line number
-2000
2000
0
_BLx
Reverse software limit
counts
-2147483648
2147483647
-2147483648
_BN
Serial number of the SMC–4000
n/a
1
65535
n/a
_CEx
Type of encoder selected
configuration
0
15
0
_CF
Returns the default port that unsolicited messages are directed to
(ASCII)
configuration
65 = 'A'
83 = 'S'
83 = 'S'
_CM
Is the contour mode buffer full?
status
0=NO
1=YES
0=NO
_CN
Returns the configuration of the limit switches
configuration
-1 = Active Low 1 = Active High -1 = Active Low
_CN1
Returns the configuration of the home input
configuration
-1 = Active Low 1 = Active High -1 = Active Low
_CN2
Returns the configuration of the latch input
configuration
-1 = Active Low 1 = Active High -1 = Active Low
_CN3
Returns the configuration of the selective abort function
configuration
_CS
Current segment number for Vector Mode
segment
0
511
0
_CW
Port #1 data adjustment (MG from prog, chars have bit 8 set)
status
1=SET
2=OFF
2=OFF
_DA
Number of available arrays
quantity
0
30
30
_DCx
Axis deceleration rate
counts/sec2
1024
67107840
256000
_DEx
Encoder position of the auxiliary encoder
counts
-2147483648
2147483647
n/a
_DL
Number of available labels
quantity
0
510
510
_DM
Number of available array locations
quantity
0
2000
2000
_DPx
Current encoder position of axis
counts
-2147483648
2147483647
n/a
_DT
Time interval for contour mode
2N mSec
0
8
0
_DVx
Is the axis using dual loop PID?
status
0=NO
1=YES
0=NO
_EB
Is CAM mode enabled?
status
0=NO
1=YES
0=NO
_EC
returns the current index into the cam table
pointer
0
1024
0
_ED
The last line that caused a CMDERR
line number
0
999
n/a
_EGx
Is CAMMING axis engaged?
status
0=NO
1=YES
0=NO
_EMx
Cam cycle for camming (master or slave)
counts
0
2147483647
0
_EO
Is echo mode on?
status
0=NO
1=YES
0=NO
_EP
CAMMING interval (resolution)
counts
1
32767
256
_EQx
Status of ECAM slave
status
0
3
0
_ERx
Axis following error limit
counts
0
32767
16384
_ES
Ellipse scale ratio
n/a
0.0001
1
1
_FAx
Axis acceleration feedforward
constant
0
8191
0
_FLx
Forward software limit
counts
-2147483648
2147483647
2147483647
_FVx
Axis velocity feedforward
constant
0
8191
0
_GRx
Gear ratio of the axis
constant
-127.9999
127.9999
0
_HMx
State of the home switch
status
0=ACTIVE
1=INACTIVE
n/a
_HXx
Thread info (x is thread 0 through 3)
0=NOT
RUNNING
1=RUNNING
2=AT
TRIPPOINT
n/a
_IA
Returns the IP address as a 32 bit signed number
address
0
2147483647
0
_IA1
Returns the Ethernet retry time
mSec
0
2147483647
250
_IA2
Returns the number of available handles
handles
0
8
8
_IA3
Returns the number of the handle using this operand
handle
0
5
n/a
_IHh0
Returns the IP address as a 32 bit signed number ("h" is handle
"A" - "H")
address
-2147483648
2147483647
-1