DESCRIPTION:

The WC command acts as a flag in the Contour Mode. After this command is executed, the controller does
not receive any new data until the internal contour data buffer is ready to accept new commands. This
command prevents the contour data from overwriting itself in the contour data buffer.

USAGE:

RELATED COMMANDS:

CM (Contour Mode)

CD (Contour Data)

DT (Delta Time)

EXAMPLES:

While Moving

Yes

Default Value

---

In a Program

Yes

Default Format

---

Command Line

Yes

Can be Interrogated

No

Used as an Operand

No

CM

Specify contour mode

DT 4

Specify time increment for contour

CD 200

Specify incremental position

WC

Wait for contour data to complete

CD 100

WC

Wait for contour data to complete

DT 0

Stop contour

CD 0