Mw (modbus wait), Configuration – Yaskawa SMC–4000 User Manual

Page 172

background image

162

SMC–4000 User Manual

MW (Modbus Wait)

[Configuration]

DESCRIPTION:

The MW command sets the controller to wait for the ACK signal from a remote I/O device before going to
the next command. With this setting disabled, the controller will continue executing commands after an I/O
command that requires it to send a modbus packet. In this mode, the I/O state cannot be guaranteed.
Enabling this setting is the default, and is recommended. This is a configuration command and only needs to
be set once in the program. This configuration is not burnable, and is set to “enabled” at power up.

ARGUMENTS: MW n

where

n is 0 to disable the Modbus Wait function.

n is 1 to enable the Modbus Wait function.

USAGE:

OPERAND USAGE:

_MW contains the contains current setting of the MW command.

RELATED COMMANDS:

CB (Clear Bit)

MB (Modbus)

SB (Set Bit)

EXAMPLES:

Typically this command would be set once at the top of the application program.

While Moving

Yes

Minimum Value

0

In a Program

Yes

Maximum Value

1

Command Line

Yes

Default Value

0

Can be Interrogated

Yes

Used as an Operand

Yes

MW1

Enable Modbus Wait function.