DESCRIPTION:
The IA command assigns the controller an IP address.
The IA command may also be used to specify the time out value. This is only applicable when using the
TCP/IP protocol.
The IA command can only be used via RS-232. Since it assigns an IP address to the controller,
communication with the controller via internet cannot be accomplished until after the address has been
assigned.
ARGUMENTS: IA ip0,ip1, ip2, ip3 or IA n or IA
ip0, ip1, ip2, ip3 are 1 byte numbers separated by commas and represent the individual fields of the IP
address.
n is the IP address for the controller which is specified as an integer representing the signed 32 bit number
(two’s complement).
USAGE: OPERAND USAGE: _IA0 contains the IP address representing a 32 bit signed number (Two’s complement) _IA1contains the value for t (retry time) _IA2 contains the number of available handles _IA3 contains the number of the handle using this operand where the number is 0 to 7. 0 represents handle A, 1 handle B, etc. _IA4 reports the last handle that had a TCP error. RELATED COMMANDS: EXAMPLES: While Moving No Default Value n = 0, t=250 In a Program Yes Default Format --- Command Line Yes IA 151, 12, 53, 89 Assigns the controller with the address 151.12.53.89 IA 2534159705 Assigns the controller with the address 151.12.53.89 IA < 500 Sets the timeout value to 500msec