beautypg.com

Eq (ecam quit (disengage)), Motion – Yaskawa SMC–4000 User Manual

Page 116

background image

106

SMC–4000 User Manual

EQ (ECam Quit (Disengage))

[Motion]

DESCRIPTION:

The EQ command disengages an electronic cam slave axis at the specified master position. If a value is
specified outside of the master’s range, the slave will disengage immediately.

ARGUMENTS: EQ n

where

n is the master position at which the axis is to be disengaged.

USAGE:

OPERAND USAGE:

_EQn contains 1 if engage command is issued and slave is waiting to engage, 2 if disengage command is
issued and slave is waiting to disengage, and 0 if ECAM engaged or disengaged.

RELATED COMMANDS:

EB (ECAM Enable)

EG (ECAM Engage)

EM (ECAM Cycle)

EP (ECam Table Intervals and Start Point)

ET (ECam Table)

EXAMPLES:

*Note This command is not a trippoint. This command will not hold the execution of the program

flow. If the execution needs to be held until master position is reached, use MF or MR
command.

While Moving

Yes

Minimum value

-2147483647

In a Program

Yes

Maximum value

2147483648

Command Line

Yes

Default Value

--

Can be Interrogated

Yes

Default Format

--

Used as an Operand

Yes

Virtual Axis

No

EQ 300

Disengages the motor at master position 300.