Event trigger - start motion on input – Yaskawa SMC–4000 User Manual
Page 319
309
SMC–4000 User Manual
Event Trigger - Start Motion on Input
This example waits for input 1 to go low and then starts motion. Note: The AI command actually halts
execution of the program until the input occurs. If you do not want to halt the program sequences, you
can use the Input Interrupt function (II) or use a conditional jump on an input, such as JP #GO,@IN[1] =
0.
Event Trigger - Set Output when at Speed
Event Trigger - Change Speed along Vector Path
The following program changes the feed rate or vector speed at the specified distance along the vector.
The vector distance is measured from the start of the move or from the last AV command.
#INPUT
Program Label
AI-1
Wait for input 1 low
PR 10000
Position command
BGX
Begin motion
EN
End program
#ATSPEED
Program Label
JG 50000
Specify jog speed
AC 10000
Acceleration rate
BGX
Begin motion
ASX
Wait for at slew speed 50000
SB1
Set output 1
EN
End program
#VECTOR
Label
VMXY;VS 5000
Coordinated path
VP 10000,20000
Vector position
VP 20000,30000
Vector position
VE
End vector
BGS
Begin sequence
AV 5000
After vector distance
VS 1000
Reduce speed
EN
End
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)