H3C Technologies H3C WX3000 Series Unified Switches User Manual
Page 39
1-2
Therefore, when you use the NMS to manage the access control engine and the switching engine on
the same interface, you must first obtain the management IP addresses of the two SNMP agents and
obtain the link relationship between them, and then you can access the two agents. By default, the
management IP address of an OAP module is not configured.
Before configuring the management IP address of the OAP software system, you must configure the
same IP address at the engine side where the OAP software system resides; otherwise, the NMS
cannot access the OAP software system by using the configured management IP address.
Follow these steps to configure the management IP address of the OAP software system:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the management IP
address of an OAP module
oap management-ip ip-address
slot 0
Required
Not configured by default.
Configuring the Management IP Address of the OAP Software System on the Switching
Engine
1) Configure the management IP address of the OAP software system on the switching engine side.
[device_LSW] interface vlan-interface 1
[device_LSW-Vlan-interface1] ip address 192.168.0.2 24
Press Ctrl+K to return to the command line operating interface of the access control engine.
2) Configure the management IP address of the SNMP agent on the access control engine.
[device] oap management-ip 192.168.0.2 slot 0
Configuring the Management IP Address of the OAP Software System of the
Access Control Engine
1) Configure the management IP address of the OAP software system on the access control engine
side.
[device] interface Vlan-interface 1
[device-Vlan-interface1] ip address 192.168.0.1 24
2) Log in to the switching engine, and configure the management IP address of the SNMP agent on
the switching engine.
Connected to OAP!
[device_LSW] oap management-ip 192.168.0.1 slot 0