Configuration procedure, Configuring gvrp timers – H3C Technologies H3C WX3000 Series Unified Switches User Manual
Page 111
14-5
Configuration procedure
Follow these steps to enable GVRP on an Ethernet port:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable GVRP globally
gvrp
Required
By default, GVRP is disabled globally.
Enter Ethernet port view
interface interface-type
interface-number
—
Enable GVRP on the port
gvrp
Required
By default, GVRP is disabled on the port.
After you enable GVRP on a trunk port, you cannot change the port to a different type.
Configuring GVRP Timers
Follow these steps to configure GVRP timers:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the LeaveAll timer
garp timer leaveall timer-value
Optional
By default, the LeaveAll timer is set
to 1,000 centiseconds.
Enter Ethernet port view
interface interface-type
interface-number
—
Configure the Hold, Join, and
Leave timers
garp timer
{ hold | join | leave }
timer-value
Optional
By default, the Hold, Join, and
Leave timers are set to 10, 20, and
60 centiseconds respectively.
Note that:
z
The setting of each timer must be a multiple of 5 (in centiseconds).
z
The timeout ranges of the timers vary depending on the timeout values you set for other timers. If
you want to set the timeout time of a timer to a value out of the current range, you can set the
timeout time of the associated timer to another value to change the timeout range of this timer.
The following table describes the relations between the timers:
Table 14-2
Relations between the timers
Timer
Lower threshold
Upper threshold
Hold 10
centiseconds
This upper threshold is less than or equal to one-half
of the timeout time of the Join timer. You can change
the threshold by changing the timeout time of the Join
timer.