beautypg.com

Mks by125 low cost synchrocontroller, By125 – Delta Electronics Network Device DOP-A/AE/AS User Manual

Page 91

background image

Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series

1-90

Revision January, 2008, Doc. Name: 2007PDD23000007

MKS BY125 Low Cost Synchrocontroller

Back to Table

A. HMI factory settings

Baud rate: 9600, 7, EVEN, 1.

Controller Station number: 11

(NOTE 1)

.

Control area/status area: None / None.

B. Definition of controller Read/Write address

Registers

Read/Write Range

Register Type

Format

Word No.

Bit No.

Data Length

n: 0 ~ 17,

40 ~ 41,

45 ~ 48,

50,

Data In Register / Setup
Register

Cn

90 ~ 92

N/A Double

Word

Synchronizing (Differential
Counter)

SYN_ERRn n:

0

N/A Double

Word

Integration register

IRn

n: 0

N/A

Double Word

Actual Master speed

MAS_SPDn n:

0

N/A Double

Word

Contacts

Read/Write Range

Contact type

Format

Word No.

Bit No.

Reset RSTn

N/A

n:

0

Jog Trim+

JOGTRIM_INCn

N/A

n: 0

Jog Trim-

JOGTRIM_DECn

N/A

n: 0

Activate Data

ACT_DATAn

N/A

n: 0

Store EEPROM

STR_EEPROMn

N/A

n: 0

Index Slave

IND_SLAn

N/A

n: 0

Index Master

IND_MASn

N/A

n: 0