Siemens s7 200 plc, S7 200, Siemens – Delta Electronics Network Device DOP-A/AE/AS User Manual
Page 121
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-120
Revision January, 2008, Doc. Name: 2007PDD23000007
Siemens S7 200 PLC
A. HMI factory settings
Baud rate: 9600, 8, EVEN, 1.
Controller station number: 2.
Control area/status area: VW0 / VW10.
B. Definition of controller Read/Write address
Register
Read/Write Range
Register Type
Format
Word No.
Bit No.
Timer
Tn
n: 0 ~ 255
N/A
Analog Input Word
AIWn
n: 0 ~ 30
N/A
Counter
Cn
n: 0 ~ 255
N/A
Analog Output Word
AQWn
n: 0 ~ 30
N/A
Input Image
IWn
n: 0 ~ 14
N/A
Input Image
IDn
n: 0 ~ 12
N/A
Output Image
QWn
n: 0 ~ 14
N/A
Output Image
QDn
n: 0 ~ 12
N/A
Special Bits
SMWn
n: 0 ~ 199
N/A
Special Bits
SMDn
n: 0 ~ 197
N/A
Internal Bits
MWn
n: 0 ~ 98
N/A
Internal Bits
MDn
n: 0 ~ 96
N/A
Data Area
VWn
n: 0 ~ 9998
N/A
(DBWn)
(n: 0 ~ 9998)
Data Area
VDn
n: 0 ~ 9996
N/A
Special S
SWn
n: 0 ~ 99
N/A
Special S
SDn
n: 0 ~ 97
N/A
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Timer Bit
Tn
N/A
n: 0 ~ 255
Counter Bit
Cn
N/A
n: 0 ~ 255
Input Image
In.b
n: 0 ~ 15
b: 0 ~ 7
Output Image
Qn.b
n: 0 ~ 15
b: 0 ~ 7
Special Bit
SMn.b
n: 0 ~ 200
b: 0 ~ 7
Internal Bit
Mn.b
n: 0 ~ 99
b: 0 ~ 7
Data Area Bit
Vn.b
n: 0 ~ 9999
b: 0 ~ 7