(CONFIG:) Rx

Æ Eb/No

Eb/No Alarm: Threshold
Alarm/Fault (
E)

Select Threshold, Alarm/Fault, or Masked using the

W X

arrow keys, then press

ENTER

.

If Eb/No Alarm: Æ Threshold is selected:

Eb/No Alarm Threshold:
2.0 dB Masked (
▲ ▼ E)

The range of Eb/No alarm point values is from 0.1 to 16.0 dB. If the Eb/No falls below the
selected value, a receive traffic fault is generated.

To edit the threshold, use the

W X

arrow keys to select the digit to be edited, then use the ▲ ▼

arrow keys to change the value of the digit. Press

ENTER

when done.

If Eb/No Alarm: Æ Alarm/Fault is selected:

Eb/No Alarm:
Alarm Fault Mask (
E)

The available choices define the Eb/No Alarm as an Alarm, as a Fault, or to completely Mask
the alarm. This choice affects operation in 1:1 redundancy. Select Alarm, Fault, or Masked
using the

W X

arrow keys, then press

ENTER

.

(CONFIG:) Rx

Æ PLL

Carrier PLL Bandwidth:
1x 2x (
E)

This selection is sometimes useful when high phase noise is present. 1x is the normal operating mode.
Select 1x or 2x using the

W X

arrow keys, then press

ENTER

.