Comtech EF Data CDM-710G User Manual
Page 221
CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–31
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx FEC Type
N/A
1 byte
Query Only.
Tx FEC coding type, where:
0=Viterbi + Reed-Solomon
1=LDPC
( FEC is dependent on the TX Mode Type. )
Example: TFT=1 (which is LDPC coding)
TFT?
TFT*
TFT#
TFT? TFT=x
Tx Gold Code
Sequence Index
TGS=
6 bytes
Command or Query.
Tx Gold Code Sequence Index, where:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )
Example: TGS=189063
TGS=
TGS?
TGS*
TGS#
TGS? TGS=xxxxxx
Tx Interface
Enable
TIE=
2 bytes
Command or Query.
Interface Slot Enable/Disable, where:
s=Defines which interface slot (1 or 2)
x=Tx Interface Status, where:
0=Disabled
1=Enabled
Example: TIE =11 (Enables transmit interface)
TIE=
TIE?
TIE*
TIE#
TIE?s TIE=sx
Tx Location of
Pilot
TLP=
1 byte
Command or Query.
Tx Pilot On/Off selection, where:
0=average,
1=Peak
Example: TLP=0 (which is Pilot Average)
TLP=
TLP?
TLP*
TLP#
TLP? TLP=x
Tx Line Code
TLC=
2 bytes
Command or Query. (G.703 Parameters)
Tx Line Code, where:
s=Defines which interface slot ( 1 or 2 )
x=Defines Tx Line Code, where:
0=None ( Valid for E3, T3, and STS-1 )
1=HDB3 (Valid for E3 )
2=B3ZS ( Valid for T3 and STS-1)
Note: Command valid only with CDI-10-1 G.703 interface.
Example: TLC=11 (sets Line Code to HDB3 for interface 1 channel 1)
TLC=
TLC?
TLC*
TLC#
TLC?s
TLC=sx
(see description of
arguments)
Tx Pilot On/Off
TPI=
1 byte
Command or Query.
Tx Pilot On/Off selection, where:
0=Off,
1=On
Example: TPI=0 (which is Pilot Off)
TPI=
TPI?
TPI*
TPI#
TPI? TPI=x