beautypg.com

Comtech EF Data CDM-710G User Manual

Page 221

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–31

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx FEC Type

N/A

1 byte

Query Only.
Tx FEC coding type, where:
0=Viterbi + Reed-Solomon
1=LDPC
( FEC is dependent on the TX Mode Type. )

Example: TFT=1 (which is LDPC coding)

TFT?
TFT*
TFT#

TFT? TFT=x

Tx Gold Code
Sequence Index

TGS=

6 bytes

Command or Query.
Tx Gold Code Sequence Index, where:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )
Example: TGS=189063

TGS=
TGS?
TGS*
TGS#

TGS? TGS=xxxxxx

Tx Interface
Enable

TIE=

2 bytes

Command or Query.
Interface Slot Enable/Disable, where:

s=Defines which interface slot (1 or 2)
x=Tx Interface Status, where:
0=Disabled
1=Enabled

Example: TIE =11 (Enables transmit interface)

TIE=
TIE?
TIE*
TIE#

TIE?s TIE=sx

Tx Location of
Pilot

TLP=

1 byte

Command or Query.
Tx Pilot On/Off selection, where:
0=average,
1=Peak

Example: TLP=0 (which is Pilot Average)

TLP=
TLP?
TLP*
TLP#

TLP? TLP=x

Tx Line Code

TLC=

2 bytes

Command or Query. (G.703 Parameters)
Tx Line Code, where:

s=Defines which interface slot ( 1 or 2 )
x=Defines Tx Line Code, where:
0=None ( Valid for E3, T3, and STS-1 )
1=HDB3 (Valid for E3 )
2=B3ZS ( Valid for T3 and STS-1)

Note: Command valid only with CDI-10-1 G.703 interface.

Example: TLC=11 (sets Line Code to HDB3 for interface 1 channel 1)

TLC=
TLC?
TLC*
TLC#

TLC?s

TLC=sx
(see description of
arguments)

Tx Pilot On/Off

TPI=

1 byte

Command or Query.
Tx Pilot On/Off selection, where:
0=Off,
1=On

Example: TPI=0 (which is Pilot Off)

TPI=
TPI?
TPI*
TPI#

TPI? TPI=x

This manual is related to the following products: