If Interface Æ RS232 is selected:
In RS232 Mode the Bus
Address is fixed at 0000
If Interface Æ RS485 is selected, the user will be further prompted:
RS485 Mod Address: 0001
(E)
The valid range of addresses is from 1 to 9999. To edit the RS485 address of the modem, use the
W X
arrow keys to select the digit to be edited, then use the
ST
arrow keys to change the value of
the digit. Press
ENTER
when done.
If Serial CONFIG: Æ Baudrate is selected:
Local M&C Bus Baud Rate:
9600 Baud ( E )
Values of 1200, 2400, 4800, 9600, 19200, 38400, and 57600 baud are possible for the Baud rate
of the remote control bus connected locally to the M&C computer. Use the
ST
arrow keys to
change the value, then press
ENTER
.
Note: The Asynchronous character format is FIXED at 8 data bits, No parity, and 1 stop bit (8-N-1).
(CONFIG:) Remote Control
Æ Ethernet
Ethernet CONFIG: Gateway
Address MAC SNMP ( E)
Select Gateway, Address, MAC, or SNMP using the
W X
arrow keys, then press
ENTER
.
If Ethernet CONFIG: Æ Gateway is selected:
Ethernet IP Gateway:
063.168.001.127 ( E )
Use the ◄ ► arrow keys to select the digit to be edited, then use the
W X
arrow keys to change the
value of the digit. Press
ENTER
when done.
If Ethernet CONFIG: Æ Address is selected:
Ether IP Address/Range:
192.168.001.001/24 ()
The range is adjustable from 08 to 30. Use the
W X
arrow keys to select the digit to be edited, then
use the
ST
arrow keys to change the value of the digit. Press
ENTER