beautypg.com

Comtech EF Data CDM-710G User Manual

Page 229

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–39

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Number of
Unread stored
Events

N/A 3

bytes

Query

Only.

Unit returns the Number of stored Events, which remain Unread, in the
form xxx.

Note: This means unread over the remote control.

Example: NUE=126

NUE?
NUE*
NUE#

NUE? NUE=xxx

Rx Alpha Rolloff RAR=

1 byte

Command or Query.
Rx Alpha Rolloff, where:
0 = 20%
1 = 25%
2 = 35%

Example: RAR=0 (which is a Rx Alpha Rolloff of 20%)

RAR=
RAR?
RAR*
RAR#

RAR? RAR=x

Rx Buffer Size

RBS=

5 bytes

Command or Query.
Rx Buffer Size (in milliseconds), where:
s=Defines which interface slot ( 1 or 2 )
xx.x= Rx Buffer Size,
HSSI = 5.0 to 32.0 ms, in 0.1 ms steps
GBEI = N/A
E3T3STS1= .5 TO 64 MS IN.5MS STEPS

Example: RBS=130.0 (selects 30.0 ms on interface 1)

RBS=
RBS?
RBS*
RBS#

RBS?s

RBS=sxx.x
(see description of
arguments)

Soft Reboot

RBT=1

1 byte

Command Only.
Soft Reboot.
1= Reboot System

RBT=
RBT?
RBT*
RBT#

N/A RBT=x

Rx Clock
Invert

RCI=

2 bytes

Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted

Note: Command valid only with HSSI.

Example: RCI = 11 (selects Inverted RX Clock, Slot 1)

RCI =
RCI?
RCI *
RCI #

RCI?s

RCI =sx
(see description of
arguments)

Rx Data Invert

RDI=

2 bytes

Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 )
x=Invert Receive Data, where:
0=Normal
1=Inverted

Note: Command valid with HSSI or E3T3STS1.

RDI =
RDI?
RDI*
RDI#

RDI?sc

RDI =sx
(see description of
arguments)

This manual is related to the following products: