Comtech EF Data CDM-710G User Manual
Page 229
CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–39
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Number of
Unread stored
Events
N/A 3
bytes
Query
Only.
Unit returns the Number of stored Events, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: NUE=126
NUE?
NUE*
NUE#
NUE? NUE=xxx
Rx Alpha Rolloff RAR=
1 byte
Command or Query.
Rx Alpha Rolloff, where:
0 = 20%
1 = 25%
2 = 35%
Example: RAR=0 (which is a Rx Alpha Rolloff of 20%)
RAR=
RAR?
RAR*
RAR#
RAR? RAR=x
Rx Buffer Size
RBS=
5 bytes
Command or Query.
Rx Buffer Size (in milliseconds), where:
s=Defines which interface slot ( 1 or 2 )
xx.x= Rx Buffer Size,
HSSI = 5.0 to 32.0 ms, in 0.1 ms steps
GBEI = N/A
E3T3STS1= .5 TO 64 MS IN.5MS STEPS
Example: RBS=130.0 (selects 30.0 ms on interface 1)
RBS=
RBS?
RBS*
RBS#
RBS?s
RBS=sxx.x
(see description of
arguments)
Soft Reboot
RBT=1
1 byte
Command Only.
Soft Reboot.
1= Reboot System
RBT=
RBT?
RBT*
RBT#
N/A RBT=x
Rx Clock
Invert
RCI=
2 bytes
Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted
Note: Command valid only with HSSI.
Example: RCI = 11 (selects Inverted RX Clock, Slot 1)
RCI =
RCI?
RCI *
RCI #
RCI?s
RCI =sx
(see description of
arguments)
Rx Data Invert
RDI=
2 bytes
Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 )
x=Invert Receive Data, where:
0=Normal
1=Inverted
Note: Command valid with HSSI or E3T3STS1.
RDI =
RDI?
RDI*
RDI#
RDI?sc
RDI =sx
(see description of
arguments)