CDM-710G High-Speed Satellite Modem

Revision 1

Front Panel Operation

MN-CDM710G

6–8

6.3.1.1

(CONFIG:) Remote Control

Remote Control:
Local Serial Ethernet

Select Local, Serial or Ethernet using the

W X

arrow keys, then press

ENTER

. Note the

following:

SELECTION ACTION

Local

Remote control is disabled. Remote monitoring is still possible.

Serial

RS232, RS485-2W, and RS485-4W menus are accessed.

Ethernet

Additional sub-menus will be displayed.

(CONFIG:) Remote Control

Æ Local

IMPORTANT

When Local is selected, remote control is disabled and local control enabled.
Once ENTER is pressed, the user is returned to the CONFIG: menu.

When Remote is selected, menu operations associated with Local control are
disabled, and the user may see the following messages and prompts when
menu or command access associated with Local control is attempted (follow
the prompt as shown):

THIS UNIT IS CURRENTLY
IN REMOTE MODE!!


DO YOU WANT IN LOCAL
MODE? ENT=Yes CLR=No

(CONFIG:) Remote Control

Æ Serial

Serial CONFIG:
Interface Baudrate (
E)

Select Interface or Baudrate using the

W X

arrow keys, then press

ENTER

.

If Serial CONFIG: Æ Interface is selected:

M&C Bus Interface: RS232
RS485-2W RS485-4W (
E)

Select RS232 or RS485-2W (2-wire) or RS485-4W (4-wire) using the

W X

arrow keys, then

press

ENTER

.

Note: At this point the user will be further prompted to enter the bus address.