beautypg.com

Config:) rx ( code, Config:) rx æ code – Comtech EF Data CDM-710G User Manual

Page 95

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Front Panel Operation

MN-CDM710G

6–19

If Rx Demod: Æ Eq is selected:

Rx Adaptive Equalizer:
Off On

(E)

The adaptive equalizer helps correct for linear distortion in the rest of the link. Linear distortion
includes amplitude and phase that would occur due to imperfect filtering effects, but it does not
include distortion due to non linear amplifiers. Select operation as Off or On using the

W X

arrow

keys, then press

ENTER

.

If Rx Demod: Æ IQ-TP is selected:

Rx IQ TPs (J2-11,J2-3):
Pre-EQ Post-EQ

(E)

This selection determines whether the IQ test point located on the Alarm Connector samples the
IQ signal before or after the Adaptive Equalizer. J2-11 and J2-3 refer to the pins on the Alarm
Connector that an oscilloscope is connected to monitor I and Q. Select Pre-Eq or Post-Eq using
the

W X

arrow keys, then press

ENTER

.

If Rx Demod: Æ Pilot is selected:

Rx Demodulation Pilot:
Off

O

n

(E)

This menu is read-only, as the demodulator automatically determines if the pilots are On or
Off
. Press

ENTER

or

CLEAR

to return to the previous menu.

If Rx Demod: Æ Scr (Descrambler) is selected:

Rx Descrambling Index:
Gold-n = 000000 (
▲ ▼ E)

The Gold-n Index indicates the Physical Layer spreading sequence number, and can be set from 0 to
262,141. The default setting is all 0s.

To edit the index, use the

W X

arrow keys to select the digit to be edited, then use the

ST

arrow

keys to change the value of the digit. Press

ENTER

when done.

(CONFIG:) Rx

Æ Code

Code Rate: 1/2 3/5 2/3
3/4 4/5 5/6 7/8 8/9 9/10

This menu is read-only, as the demodulator automatically resolves the code rate. Press

ENTER

or

CLEAR

to return to the previous menu.