Errata A for MN‐CDM710G Rev 1
Update 'FLT' Serial Remote Control Query
ER-CDM710G-EA1
THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0025029
Page 4 of 4
A= TX Clock Failure (Interface 2)
B= GBEI Card Data rate > + 200 PPM
C= GBEI Card Data rate < - 200 PPM
D= GBEI No PHY Link
E= Encoder FIFO Empty
F= Encoder FIFO Full
G= SERDES Parity Errors
H=Reserved.
I=Tx Ais Interface 1
J=Tx Ais Interface 2
K=Tx Cable Interface 1
L=Tx Cable Interface 2
c=Rx Traffic Status
0=No faults
d=New Faults
0=No new faults
1=New faults, since last check
e=Configuration change
0=Modem configuration has not been changed
1= Modem configuration has been changed