Comtech EF Data CDM-710G User Manual
Page 232

CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–42
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Signal Level
N/A
3 bytes
Query Only.
Unit returns the value of the Rx signal level, in dBm, between +3.0 and –
99.0 dBm, where;
xxx is the Rx signal level.
Examples:
RSL=+03
RSL=-41
RSL?
RSL*
RSL#
RSL? RSL=xxx
Rx Demod
Acquisition
Sweep Width
RSW=
3 bytes
Command or Query.
Rx
± acquisition sweep range of demodulator, in kHz, ranging from ± 1 to ±
100 kHz.
Example: RSW=009 (selects
± 9 kHz)
RSW=
RSW?
RSW*
RSW#
RSW? RSW=xxx
(see description of
arguments)
Gigabit Learning
Mode
SLM
2 bytes
Command or Query.
s=Slot 2 Only
a=1 GBEI Learning Enabled.
a=0 GBEI Learning Disabled
SLM=
SLM#
SLM?
SLM*
SLM?s SLM=a
Gigabit Auto
Autocrossover
SCX
2 bytes
Command or Query.
s=Slot 2 Only
a=1 GBEI Cable Auto Crossover Enabled.
a=0 GBEI Cable Auto Crossover Disabled
SCX=
SCX#
SCX?
SCX*
SCX?s SCX=a
Serial Number
N/A
9 bytes
Query Only.
Used to query the unit 9-digit serial number. Unit returns its S/N in the form
xxxxxxxxx.
Example: SNO=176500143
SNO?
SNO*
SNO#
SNO? SNO=xxxxxxxxx
Software
Revision
N/A
5 bytes
Query Only.
Unit returns the value of the internal software revision installed in the unit,
in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z
Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0
SWR?
SWR*
SWR#
SWR?
SWR=Boot:X.X.X
Bulk1:Y.Y.Y Bulk2:Z.Z.Z
Real-time Clock
Time
TIM=
6 bytes
Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
TIM=
TIM?
TIM*
TIM#
TIM?
TIM=hhmmss
Temperature N/A
3
bytes
Query
Only.
Unit returns the value of the internal temperature, in the form of sxxx
(degrees C). Where s is the sign and and xxx is the number of degrees.
Example: TMP=+026
TMP?
TMP*
TMP#
TMP? TMP=sxxx