Comtech EF Data CDM-710G User Manual
Page 201
![background image](https://www.manualsdir.com/files/778753/content/doc201.png)
CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–11
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Unit Alarm
Mask
MSK=
13 bytes
Command or Query.
Alarm mask conditions, in form ab, where:
a=Tx Cable Slot 1
b=Tx AIS Slot 1
c=Rx AIS Slot 1
d=Bufferslip Alarm Slot 1
e=External Clock Alarm Slot 1
f=Tx Cable Slot 2
g=Tx AIS Slot 2
h=Rx AIS Slot 2
i=Bufferslip Alarm Slot 2
j=External Clock Alarm Slot 2
k=EBNO Alarm
L=Ber Alarm
m=Rx AGC Alarm xxx -spares
Mask (Alarm=0, Fault = 1,Masked =2))
Example: MSK=110101100000xxx ( alarm masks for Interface Slot 1 ,Slot 2 ,
MSK=
MSK?
MSK*
MSK#
MSK? MSK=abcdefghijkLmxxx
Soft Reboot
RBT=1
1 byte
Command Only.
Soft Reboot.
1= Reboot System
RBT?
RBT*
RBT#
N/A RBT=
Retrieve next 5
unread Stored
Events
N/A 75
bytes
Query
Only.
Unit returns the oldest 5 Stored Events which have not yet been read over
the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where:
Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.
RNE?
RNE*
RNE#
RNE? RNE={CR}ABCddmmyyh
hmmss{CR}ABCddmmyy
hhmmss{CR}ABCddmm
yyhhmmss{CR}ABCddm
myyhhmmss
{CR}ABCddmmyyhhmm
ss