A–46

[Unit Block] consists of 20 bytes for Unit Configuration. The format is: ab ccccccccccccccccdx

a = Test Mode

same as TST

b

=

Reserved

cccccccccccccccc = Alarm Mask

same as MSK

d = External Reference Frequency same as ERF

x = Spare bytes.

[Interface Block] consists of 130 bytes and contains the configuration of the current enabled interface on the unit. The format of the
configuration bytes depend on the interface type indicated by the 5

th

byte in the MGC query or command.

If E3T3STS1 interface, then format is: abcdeff.fx…xxx

a = Tx Data Inversion

same as TDI (omit interface slot parameter)

b = Rx Data Inversion

same as RDI (omit interface slot parameter)

c = Rx Clock Source

same as RCK (omit interface slot parameter)

dd.d = Rx Buffer Size

same as RBS (omit interface slot parameter)

f= ET3STS1 Type

same as ETS (omit interface slot parameter)

e = E3T3STS1 Rx FRAME

same as RFM (omit interface slot parameter)

g= E3T3STS1 Tx Line Code

same as TLC (omit interface slot parameter)

h=E3T3STS1 External Ref same as EFI (omit interface slot parameter)

If Gigabit Ethernet interface then format is: ab…xxxx

a=autocrossover
b=learning

If HSSI interface, then format is: abcdeff.fx…xxx

a = Tx Data Inversion

same as TDI (omit interface slot parameter)

b = Rx Data Inversion

same as RDI (omit interface slot parameter)

c = Tx Clock Inversion

same as TCI (omit interface slot parameter)

d = Rx Clock Inversion

same as RCI (omit interface slot parameter)

e = Rx Clock Source

same as RCK (omit interface slot parameter)

ff.f = Rx Buffer Size

same as RBS (omit interface slot parameter)

x…xxx = spare bytes

This manual is related to the following products: