beautypg.com

Comtech EF Data CDM-710G User Manual

Page 204

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–14

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Real-time Clock
Time

TIM=

6 bytes

Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)

Example: TIM=231259 (23 hours:12 minutes:59 seconds)

TIM=
TIM?
TIM*
TIM#

TIM? TIM=hhmmss

Tx Location of
the Pilot

TLP=

1 byte

Command or Query.
Tx Pilot On/Off selection, where:
0=Average,
1=Peak

Example: TLP=0 (which is Pilot Average)

TLP=
TLP?
TLP*
TLP#

TLP? TLP=x

Temperature N/A

3

bytes

Query

Only.

Unit returns the value of the internal temperature, in the form of sxxx
(degrees C). Where s is the sign and and xxx is the number of degrees.

Example: TMP=+026

TMP?
TMP*
TMP#

TMP? TMP=sxxx

Tx Pilot On/Off

TPI=

1 byte

Command or Query.
Tx Pilot On/Off selection, where:
0=Off,
1=On

Example: TPI=0 (which is Pilot Off)

TPI=
TPI?
TPI*
TPI#

TPI? TPI=x

Tx Power Level

TPL=

5 bytes

Command or Query.
Tx Output power level, where:

s=sign ( + / - )
xx.x = Tx Output power level, +05.0 and –20.0 dBm.
L-Band: -25.0 to –05.0 dBm
70/140 MHz: -20.0 to +00.0 dBm

Note: Beyond –20 dBm is beyond the specification.

Example: TPL = -13.4

TPL=
TPL?
TPL*
TPL#

TPL?

TPL=sxx.x

Tx Spectrum
Invert

TSI=

1 byte

Command or Query.
Tx Spectrum Invert selection, where:
0=Normal
1=Tx Spectrum Inverted

Example: TSI=0 (which is normal)

TSI=
TSI?
TSI*
TSI#

TSI? TSI=x

Unit Test Mode

TST=

1 byte

Command or Query.
Test Mode, where:
0=Normal Mode (no test)
1=IF Loop
2=I/O Loop
3=RF Loop
4=Tx CW
5=Tx Alternating 1,0 Pattern

Example: TST=4 (Tx CW)

TST=
TST?
TST*
TST#

TST? TST=x

This manual is related to the following products: