beautypg.com

Comtech EF Data CDM-710G User Manual

Page 203

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–13

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Data Invert

TDI=

2 bytes

Command or Query.
Invert Transmit Data, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Transmit Data, where:
0=Normal
1=Inverted

Note: Command valid with HSSI or E3T3STS1)

Example: TDI = 11 (selects Inverted TX Data)

TDI =
TDI?
TDI *
TDI #

TDI?sc

TDI =sx
(see description of
arguments)

Tx Data Rate

N/A

10 bytes

Query Only.
Composite Tx Data rate, in kbps.
Resolution=1 bps.

Example: TDR=002047.999 (which is 2047.999 kbps)

TDR?
TDR*
TDR#

TDR? TDR=xxxxxx.xxx

Tx Frequency

TFQ=

9 bytes

Command or Query.
Tx Frequency (in MHz)
52 to 88 MHz, and 104 to 176 MHz (70/140 Modulator)
950 to 1950 MHz (L-Band Modulator)
Resolution=100Hz.

Example: TFQ=0950.0000

TFQ=
TFQ?
TFQ*
TFQ#

TFQ? TFQ=xxxx.xxxx

Tx Frame Size

TFS=

1 byte

Command or Query.
Tx Frame Size Long/Short selection, where:
0=Short,
1=Long
Example: TFS =0 (which is Short FEC Frame Size)

TFS =
TFS?
TFS *
TFS #

TFS? TFS

=x

Tx FEC Type

N/A

1 byte

Query Only.
Tx FEC coding type, where:
1=LDPC
( FEC is dependent on the TX Mode Type. )

Example: TFT=1 (which is LDPC coding)

TFT?
TFT*
TFT#

TFT? TFT=x

Tx Gold Code
Sequence Index

TGS=

6 bytes

Command or Query.
Tx Gold Code Sequence Index:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )

Example: TGS=189063

TGS=
TGS?
TGS*
TGS#

TGS? TGS=xxxxxx

Tx Interface
Enable

TIE=

2 bytes

Command or Query.
Interface Slot Enable/Disable, where:
s=Defines which interface slot (1 or 2)
x=Tx Interface Status, where:
0=Disabled
1=Enabled

Example: TIE =11 (Enables transmit interface)

TIE=
TIE?
TIE*
TIE#

TIE?s TIE=sx

This manual is related to the following products: