Comtech EF Data CDM-710G User Manual
Page 206

CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–16
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Symbol Rate RSR=
9 bytes
Command or Query.
Rx Symbol Rate, where:
s=Symbol Rate in Msps
Example: RSR=20.000000 (20 Msps.)
*NOTE: Please refer to Sect. 1.8 Summary of Specifications for a list of
available code rates for each modulation type.
RSR=
RSR?
RSR*
RSR#
RSR? RSR=ss.ssssss
Enable/Disable
Adaptive
Equalizer
AEQ=
1 byte
Command or Query.
Adaptive Equalizer status, where:
0=Disable
1=Enable
Example: AEQ=1 (which is Enable)
AEQ=
AEQ?
AEQ*
AEQ#
AEQ? AEQ=x
Buffer Fill State
N/A
3 bytes
Query only.
s=Defines which interface slot ( 1 or 2 )
xx = value of the buffer fill state, between 1 to 99%. Returns 00 if
demodulator is unlocked.
Note: Command not valid for Gigabit interface.
Example: BFS=133 (which is 33%, on interface slot 1 channel 1)
N/A BFS?s
BFS=sxx
Rx BER Alarm
Threshold
BTH
1bytes
Command or Query.
Sets and Returns BerThreshold
a=Ber Threshold
0= NONE
3= 1E10-3
4 =1E10-4
5= 1E10-5
6= 1E10-6
7= 1E10-7
8 =1E10-8
Example BTH=3(Sets Ber Alarm Threshold to 1E10-3)
BTH=
BTH?
BTH#
BTH=a BTA=a
Clear All Stored
Events
CAE= None Command
Only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments
CAE=
CAE?
CAE*
CAE#
N/A N/A
Circuit ID String
CID=
24 bytes
Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed length of
24 characters.
Valid characters include: Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=xxxxxxxxxxxxxxxxx
xxxxxxx
Configuration
Load
CLD= 1
byte Command
Only.
Retrieves a previously stored configuration from the specified configuration
location (0 to 9).
Example: CLD=4 (retrieve configuration from location 4)
CLD=
CLD?
CLD*
CLD#
N/A N/A