10/100/1000 Base-T Gigabit Ethernet (GigE) Interface (CDI-70)
MN-CDM710G
14–8
f) The CReflash.exe executable automatically FTPs the filename to the IP address entered,
and displays the progress of the update.
IMPORTANT
Once the CReflash.exe application has been started, the program will
not respond to user input for approximately 5 minutes. During this
time, a message indicating this progress phase will also display on the
modem’s front panel.
DO NOT CLOSE THE CR
EFLASH
.EXE PROGRAM ON THE PC!
DO NOT REBOOT THE MODEM!
g) When the update is complete: The message 'Successful!' appears in the [ / ] status field
of the CReflash.exe application window; a similar message displays on the modem’s
front panel.
h) Cycle power to the CDM-710G to have the new firmware loaded on the GBEI.
i) Verify that the version update has successfully loaded upon reboot:
• From the CDM-710G front panel: SELECT: UTILÆ FirmwareÆ InfoÆ Image#
(Image1 or Image2)Æ InterfacesÆ GBEI
• From the Serial Console port: View the GBEI information by selecting
Operations, then selecting Maintenance/Unit Information.
• From Telnet via the 10/100 Ethernet Traffic port: View the GBEI information by
selecting Operations, then selecting Maintenance/ Unit Information.
• From HTTP Web Server Inteface via the 10/100 Ethernet Traffic port: View the
GBEI information by selecting the MAINT tab, then selecting the Unit Info
hyperlink.