beautypg.com

Comtech EF Data CDM-710G User Manual

Page 216

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–26

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Signal Level

N/A

3 bytes

Query Only.
Unit returns the value of the Rx signal level, in dBm, between +3.0 and –
99.0 dBm, where;

xxx is the Rx signal level.

Examples: RSL=+03

RSL=-41

RSL?
RSL*
RSL#

RSL? RSL=xxx

Rx Demod
Acquisition
Sweep Width

RSW=

3 bytes

Command or Query.
Rx

± acquisition sweep range of demodulator, in kHz, ranging from ± 1 to ±

100 kHz.

Example: RSW=009 (selects

± 9 kHz)

RSW=
RSW?
RSW*
RSW#

RSW? RSW=xxx

(see description of
arguments)

Gigabit Auto
Autocrossover

SCX

2 bytes

Command or Query.

s=Slot2 Only
a= 1 GBEI Cable Auto Crossover Enabled.
a=0 GBEI Cable Auto Crossover Disabled

SCX=
SCX#
SCX?
SCX*

SCX?s SCX=a

Gigabit
Learning Mode

SLM

2 bytes

Command or Query.

s=Slot2 Only
a= 1 GBEI Learning Enabled.
a=0 GBEI Learning Disabled

SLM=
SLM#
SLM?
SLM*

SLM?s SLM=a

Serial Number

N/A

9 bytes

Query Only.
Used to query the unit 9-digit serial number. Unit returns its S/N in the form
xxxxxxxxx.

Example: SNO=176500143

SNO?
SNO*
SNO#

SNO? SNO=xxxxxxxxx

Software
Revision

N/A 5

bytes

Query

Only.

Unit returns the value of the internal software revision installed in the unit,
in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z

Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0

SWR?
SWR*
SWR#

SWR? SWR=Boot:X.X.X

Bulk1:Y.Y.Y Bulk2:Z.Z.Z

Real-time Clock
Time

TIM=

6 bytes

Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)

Example: TIM=231259 (23 hours:12 minutes:59 seconds)

TIM=
TIM?
TIM*
TIM#

TIM? TIM=hhmmss

Tx Line Code

TLC=

2 bytes

Command or Query. (G.703 Parameters)
Tx Line Code, where:
s=Defines which interface slot ( 1 or 2 )
x=Defines Tx Line Code, where:
0=None ( Valid for E3, T3, and STS-1 )
1=HDB3 (Valid for E3 )
2=B3ZS ( Valid for T3 and STS-1)

Note: Command valid only with CDI-10-1Single G.703 interface

Example: TLC=11 (sets Line Code to HDB3 for interface 1 channel 1)

TLC=
TLC?
TLC*
TLC#

TLC?s

TLC=sx
(see description of
arguments)

This manual is related to the following products: