Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Carrier State TXO=

1 byte

Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON

Example: TXO=1 (Tx Carrier ON)

TXO=
TXO?
TXO*
TXO#

TXO? TXO=x

A.6.2 Demodulator

Priority System = (Highest priority) RMD, RCR, and (Lowest Priority) RSR. Any change to a higher priority parameter can override any of the
parameters of lower priority.

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Modulation
Type

N/A

1 byte

Query only.
Rx Modulation type, where:
0=QPSK
1=8PSK
2=Reserved
3=16APSK
4=32APSK

Example: RMD=1 (which is 8PSK)

*NOTE: This command is query-only because the demodulation type is
automatically detected, but if the unit is not locked, the query returns ‘x’.

RMD?
RMD*
RMD#

RMD? RMD=x

Rx FEC Code
Rate

N/A

1 byte

Query only.
Rx Code Rate, where:
0 = Rate 3/4
1 = Reserved
2 = Rate 3/5
3 = Rate 4/5
4 = Rate 5/6
5 = Rate 8/9
6 = Rate 9/10
7 = Rate 2/3
8 = Rate 1/2

Example: RCR=0 (which is Rate 3/4)

*NOTE: This command is query-only because the code rate is
automatically detected, but if the unit is not locked, the query returns ‘x’.

RCR?
RCR*
RCR#

RCR? RCR=x