A.6.2 demodulator – Comtech EF Data CDM-710G User Manual
Page 205
CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–15
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Carrier State TXO=
1 byte
Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON
Example: TXO=1 (Tx Carrier ON)
TXO=
TXO?
TXO*
TXO#
TXO? TXO=x
A.6.2 Demodulator
Priority System = (Highest priority) RMD, RCR, and (Lowest Priority) RSR. Any change to a higher priority parameter can override any of the
parameters of lower priority.
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Modulation
Type
N/A
1 byte
Query only.
Rx Modulation type, where:
0=QPSK
1=8PSK
2=Reserved
3=16APSK
4=32APSK
Example: RMD=1 (which is 8PSK)
*NOTE: This command is query-only because the demodulation type is
automatically detected, but if the unit is not locked, the query returns ‘x’.
RMD?
RMD*
RMD#
RMD? RMD=x
Rx FEC Code
Rate
N/A
1 byte
Query only.
Rx Code Rate, where:
0 = Rate 3/4
1 = Reserved
2 = Rate 3/5
3 = Rate 4/5
4 = Rate 5/6
5 = Rate 8/9
6 = Rate 9/10
7 = Rate 2/3
8 = Rate 1/2
Example: RCR=0 (which is Rate 3/4)
*NOTE: This command is query-only because the code rate is
automatically detected, but if the unit is not locked, the query returns ‘x’.
RCR?
RCR*
RCR#
RCR? RCR=x