A–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Redundancy
State

RED=

1 byte

Command or Query.
Unit returns the redundancy state of the unit, where:
0 = Offline
1 = Online
*** This command can be used to force the unit offline, this is done by
sending RED=0. This is only valid if redundancy mode is enabled. If
redundancy is not enabled, then RED=0 will return an error. The unit
cannot be forced online.
*** If the unit is not in redundancy mode, then the unit will always be online.

Example: RED=0 (force unit offline)

RED=
RED?
RED*
RED#

RED? RED=x

(see description of
arguments)

Gigabit Auto
Autocrossover

SCX

2 bytes

Command or Query.
s=Slot2 Only
a= 1 GBEI Cable Auto Crossover Enabled.
a=0 GBEI Cable Auto Crossover Disabled

SCX=
SCX#
SCX?
SCX*

SCX?s SCX=a

Gigabit
Learning Mode

SLM

2 bytes

Command or Query.
s=Slot2 Only
a= 1 GBEI Learning Enabled.
a=0 GBEI Learning Disabled

SLM=
SLM#
SLM?
SLM*

SLM?s SLM=a

Serial Number

N/A

9 bytes

Query Only.
Used to query the unit 9-digit serial number. Unit returns its S/N in the form
xxxxxxxxx.

Example: SNO=176500143

SNO?
SNO*
SNO#

SNO? SNO=xxxxxxxxx

Software
Revision

N/A 5

bytes

Query

Only.

Unit returns the value of the internal software revision installed in the unit,
in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z

Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0

SWR?
SWR*
SWR#

SWR? SWR=Boot:X.X.X

Bulk1:Y.Y.Y Bulk2:Z.Z.Z

Tx Alpha Rolloff TAR=

1 byte

Command or Query.
Tx Alpha Rolloff, where:
0 = 20%
1 = 25%
2 = 35%

Example: TAR=0 (which is a Tx Alpha Rolloff of 20%)

TAR=
TAR?
TAR*
TAR#

TAR? TAR=x

Tx Clock
Invert

TCI=

2 bytes

Command or Query.
Invert Transmit Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Transmit Clock, where:
0=Normal
1=Inverted
Note: Command valid with HSSI or E3T3STS1)

Example: TCI = 11 (selects Inverted TX Clock, Slot 1)

TCI =
TCI?
TCI *
TCI #

TCI?s

TCI =sx
(see description of
arguments)