Errata A for MN‐CDM710G Rev 1 

 

 

 

 

 

 

Update 'FLT' Serial Remote Control Query 

ER-CDM710G-EA1

THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0025029

Page 3 of 4

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Faults and
Status

N/A

4 bytes

Query Only.
Unit returns the current fault and status codes for the Unit (hardware), Tx Traffic and
Rx Traffic, in the form abcd

e

, where:

a = Unit Faults:

0=No faults
1=Framer FPGA Load
2=Power supply fault, +1.5 Volts, Framer Card
3=Power supply fault, +1.5 Volts, Interface #1
4=Power supply fault, +1.5 Volts, Interface #2
5=Power supply fault, +3.3 Volts, Framer Card
6=Power supply fault, +5.0 Volts, Framer Card
7=Power supply fault, +12.0 Volts, Framer Card
8=Power supply fault, -12.0 Volts, Framer Card
9=Power supply fauilt, +18.0 Volts, Framer Card
A=FLASH Checksum
B=FEC1 Load
C=FEC2 Load
D=Interface #1 Load
E=Interface #2 Load
F=192 MHz PLL
G=External Reference
H=Framer Card Temperature
I=Modem Temperature
J=Cooling Fans
K=Interface #1 Removed
L=Interface #2 Removed

b = Tx Traffic Status:

0=No faults
1= +1.5V Power Supply Unit (Modulator Card)
2= FPGA Failed to Load (Modulator Card)
3= Symbol Rate PLL Clock
4= Tx Synthesizer Unlocked
5= Tx Digital Clock Manager Unlocked
6= I & Q Baseband Channels are Inactive
7= FPGA Temperature (Modulator Card)
8= Reserved
9= TX Clock Failure (Interface 1)

FLT?

FLT*

FLT?

FLT=abcd

e


d=

New faults since last check

Note: Each section has faults
listed in order of priority. For
each section, only the highest
priority fault is returned. There
maybe multiple faults for each
section, but only the highest fault
is returned.