Comtech EF Data CDM-710G User Manual
Page 218

CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–28
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Buffer Fill State
N/A
3 bytes
Query only.
s=Defines which interface slot ( 1 or 2 )
xx = value of the buffer fill state, between 1 to 99%. Returns 00 if
demodulator is unlocked.
Note: Command not valid for GbEI.
Example: BFS=133 (which is 33%, on interface slot 1 channel 1)
N/A BFS?s
BFS=sxx
Interface
Reference
Clock
EFI=
2 bytes
Command or Query.
s=Defines which interface slot (1 or 2)
x=EXT CLK (Data Rate Accuracy), where:
0 = 1 MHz
1 = 2 MHz
2 = 2.048 MHz
3 = 5 MHz
4 = 10 MHz
5 = 20 MHz
6 = 34.368 MHz
7 = 44.736 MHz
8 = 51.840 MHz
Note: Command valid only with CDI-10-1 G.703 interface.
Example: EFI=14 (Selects 10MHz on slot 1)
EFI=
EFI?
EFI*
EFI#
EFI?s EFI=sx
(see description of
arguments)
E3/T3/STS1
Mode Select
ETS=
2 bytes
Command or Query.
Sets the E3/T3/STS1 interface card mode, where:
s=Interface Slot (1 or 2)
)
m=Mode
0=E3
1=T3
2=STS1
Note: Command valid only with CDI-10-1 G.703 interface. This sets the
selected G.703 data rate. The unit will adjust the symbol rate based on
modulation type and code rate to keep the selected data rate.
Example: ETS=11 (sets Interface 1, Port 1 to T3 mode)
ETS=
ETS?
ETS#
ETS*
ETS?s
ETS=sm
Gigabit
Interface
Management
MAC Address
GMC?
N/A
Query Only.
s= Slot 2 Only
Example: To get MAC address for Gigabit in Slot 2
GMC?2
GMC=2;00-06-B0-00-47-17
GMC?
GMC*
GMC#
GMC?s Gigabit
Interface
Management
MAC Address
Gigabit
Interface
Software
Revision
GSW? N/A
Query
Only.
s= Slot 2 Only
Example: To get Software Revision for Gigabit in Slot 2
GSW?2
GSW=2 FW/12738-,1.1.8,02/16/07
GSW?
GSW*
GSW#
GSW?s Gigabit
Interface
Software Revision