beautypg.com

Comtech EF Data CDM-710G User Manual

Page 222

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–32

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Power Level

TPL=

5 bytes

Command or Query.
Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +05.0 and –20.0 dBm.
L-Band: -25.0 to –05.0 dBm
70/140 MHz: -20.0 to +00.0 dBm

Note: Beyond –20 dBm is beyond the specification.

Example: TPL = -13.4

TPL=
TPL?
TPL*
TPL#

TPL?

TPL=sxx.x

Tx Spectrum
Invert

TSI=

1 byte

Command or Query.
Tx Spectrum Invert selection, where:
0=Normal
1=Tx Spectrum Inverted

Example: TSI=0 (which is normal)

TSI=
TSI?
TSI*
TSI#

TSI? TSI=x

Tx Carrier State TXO=

1 byte

Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON

Example: TXO=1 (Tx Carrier ON)

TXO=
TXO?
TXO*
TXO#

TXO? TXO=x

This manual is related to the following products: