beautypg.com

Comtech EF Data CDM-710G User Manual

Page 231

background image

CDM-710G High-Speed Satellite Modem

Revision 1

Remote Control

MN-CDM710G

A–41

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Gold Code
Sequence Index

RGS=

6 bytes

Command or Query.
Rx Gold Code Sequence Index:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )

Example: RGS=189063

RGS=
RGS?
RGS*
RGS#

RGS? RGS=xxxxxx

Rx Interface
Enable

RIE=

2 bytes

Command or Query.
Interface Slot Enable/Disable, where:

s=Defines which interface slot (1 or 2)
x=Rx Interface Status, where:
0=Disabled
1=Enabled

Example: RIE =11 (Enables receive interface)

RIE=
RIE?
RIE*
RIE#

RIE?s RIE=sx

Retrieve next 5
unread Stored
Events

N/A 75

bytes

Query

Only.

Unit returns the oldest 5 Stored Events which have not yet been read over
the remote control in the form: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where Sub-body= ABCddmmyyhhmmss:

A being the fault/clear indicator.
F=Fault
C=Clear
I=Info

B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log

C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change

If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.

RNE?
RNE*
RNE#

RNE? RNE={CR}ABCddmmyyh

hmmss{CR}ABCddmmyy
hhmmss{CR}ABCddmmy
yhhmmss{CR}ABCddmm
yyhhmmss
{CR}ABCddmmyyhhmms
s

Rx Pilot On/Off

N/A

1 byte

QueryOnly .
Rx Pilot On/Off selection, where:
0=Off,
1=On

Example: RPI=0 (which is Pilot Off)

Returns RPI=x if Demodulator unlocked.
This is automatically detected on demod acquisition.

N/A RPI?

RPI=x