CONFIG: Alarms

Note: When the unit is in Remote mode and the user attempts to select an alarm state using the

W X

arrow keys, the following message displays (follow the prompt as shown):

THIS UNIT IS CURRENTLY
IN REMOTE MODE!!

DO YOU WANT IN LOCAL
MODE?ENT=Yes CLR=No

Otherwise, the following menu is displayed:

Alarm Mask: Tx Rx
Intfc1 Intfc2 (
E)

Select Tx, Rx, Intfc1, or Intfc2 using the

W X

arrow keys, then press

ENTER

.

(CONFIG:) Alarm Mask:

Æ Tx

Tx Alarm Mask: None

Currently, masking of Tx Alarms (associated with the modulator) is not allowed.

(CONFIG:) Alarm Mask:

Æ Rx

Eb/No Threshold Alarm:
Alarm Fault Mask (
E)

Select Alarm, Fault, or Mask using the

W X

arrow keys, then press

ENTER

.

(CONFIG:) Alarm Mask:

Æ Intfc1

The appearance of the menu branch for CONFIG: Alarms (Alarm Mask:) Æ Intfc1 is
dependent on whether the CDI-10-1 Single G.703 or the CDI-60 HSSI Interface card is installed
into Interface Slot 1.

Intfc1 E3T3STS1 Alarms:
Tx Rx ExtClk (
E)

Intfc1 HSSI Alarms:
Port1 Ext-Clk (
E)