Comtech EF Data CDM-710G User Manual
Page 213
![background image](https://www.manualsdir.com/files/778753/content/doc213.png)
CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–23
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Soft Reboot
RBT=1
1 byte
Command Only..
Soft Reboot.
1= Reboot System
RBT=
RBT?
RBT*
RBT#
N/A RBT=x
ReCenter Buffer RCB=
2 bytes
Command only.
Forces the software to recenter the receive Plesiochronous/Doppler buffer.
s=Defines which interface slot ( 1 or 2 )
Example: RCB=11 (ReCenter buffer on interface 1 channel 1)
GBEI = N/A
RCB=
RCB?
RCB*
RCB#
N/A N/A
Rx Clock
Invert
RCI=
2 bytes
Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted
Note: Command valid with HSSI
Example: RCI=11 (selects Inverted RX Clock, Slot 1)
RCI =
RCI?
RCI *
RCI #
RCI?s
RCI =sx
(see description of
arguments)
Rx Clock
Source
RCK=
2 bytes
Command or Query.
Rx Clock Source (For Data Rate Accuracy), where:
s=Defines which interface slot ( 1 or 2 )
x=Rx Clock Source, where:
0=Rx Satellite
1=Tx-Terrestrial
2=External Reference Clock
3=Internal (HSSI Only)
Valid with HSSI and E3T3STS1.
Example: RCK=11 (selects Tx-Terrestrial)
RCK=
RCK?
RCK*
RCK#
RCK?s
RCK=sx
(see description of
arguments)
Rx Data Invert
RDI=
2 bytes
Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Data, where:
0=Normal
1=Inverted
Note: Command valid with HSSI or E3T3STS1.
Example: RDI=11 (selects Inverted RX Data)
RDI =
RDI?
RDI*
RDI#
RDI?s
RDI =sx
(see description of
arguments)
Rx Data Rate
N/A
10 bytes
Query Only.
Composite Rx Data rate, in kbps.
Resolution=1 bps.
Example: RDR=002047.999 (which is 2047.999 kbps)
RDR?
RDR*
RDR#
RDR? RDR=xxxxxx.xxx