Basler Electric BE1-11g User Manual
Page 661

9424200994 Rev N
649
Name
Number
INDGGIO4_IND06
1303
INDGGIO4_IND07
1304
INDGGIO4_IND08
1305
INDGGIO4_IND09
1306
INDGGIO4_IND10
1307
INDGGIO4_IND11
1308
INDGGIO4_IND12
1309
INDGGIO4_IND13
1310
INDGGIO4_IND14
1311
INDGGIO4_IND15
1312
INDGGIO4_IND16
1313
Input 1 State
665
Input 2 State
666
Input 3 State
667
Input 4 State
668
Input 5 State
862
Input 6 State
863
Input 7 State
864
Internal Use Automatic Navigation Screen
Test
803
Irig Sync Lost
736
Local Contacts Alarm Output Logic State
693
Local Contacts Alarm Output Override
Enable
681
Local Contacts Alarm Output Override
State
687
Local Contacts Alarm Output Remote
Control
699
Local Contacts Contact 52 TCM
669
Local Contacts Output 1 Logic State
688
Local Contacts Output 1 Override Enable
676
Local Contacts Output 1 Override State
682
Local Contacts Output 1 Remote Control
694
Local Contacts Output 2 Logic State
689
Local Contacts Output 2 Override Enable
677
Local Contacts Output 2 Override State
683
Local Contacts Output 2 Remote Control
695
Local Contacts Output 3 Logic State
690
Local Contacts Output 3 Override Enable
678
Local Contacts Output 3 Override State
684
Local Contacts Output 3 Remote Control
696
Local Contacts Output 4 Logic State
691
Local Contacts Output 4 Override Enable
679
Local Contacts Output 4 Override State
685
Local Contacts Output 4 Remote Control
697
Local Contacts Output 5 Logic State
692
Local Contacts Output 5 Override Enable
680
Local Contacts Output 5 Override State
686
Local Contacts Output 5 Remote Control
698
Logic Alarms AlarmOutput
1797
Logic Alarms Alarms Reset
1796
Logic Alarms New Event
1798
Logic Equal None
737
LogicLabel1
1207
LogicLabel10
1216
LogicLabel11
1217
LogicLabel12
1218
LogicLabel2
1208
LogicLabel3
1209
LogicLabel4
1210
LogicLabel5
1211
Name
Number
LogicLabel6
1212
LogicLabel7
1213
LogicLabel8
1214
LogicLabel9
1215
Major Alarm
784
Major Alarm Alarms Reset
783
Major Alarm New Event
785
Minor Alarm
787
Minor Alarm Alarms Reset
786
Minor Alarm New Event
788
No User Setting
738
NTP Sync Lost
739
NVMH Flash File Error
721
NVMH Saving Blocks Error
720
NVMH Settings File Not Opened W
718
OpPhaseA
1319
OpPhaseB
1320
OpPhaseC
1321
Output 1 - Output Override Enabled Alarm
700
Output 1 State
670
Output 10 State
836
Output 11 State
837
Output 2 - Output Override Enabled Alarm
701
Output 2 State
671
Output 3 - Output Override Enabled Alarm
702
Output 3 State
672
Output 4 - Output Override Enabled Alarm
703
Output 4 State
673
Output 5 - Output Override Enabled Alarm
704
Output 5 State
674
Output 6 - Output Override Enabled Alarm
1407
Output 6 State
832
Output 7 - Output Override Enabled Alarm
1408
Output 7 State
833
Output 8 - Output Override Enabled Alarm
1409
Output 8 State
834
Output 9 State
835
Output Alarm - Output Override Enabled
Alarm
705
Output Override
742
Phase Bus Fast Current Detected
1
Phase Bus Frequency Valid
0
PhaseCurrConfig1 Fast Current Detected
828
PhaseCurrConfig1 Unbalance Block
829
PhaseCurrConfig2 Fast Current Detected
830
PhaseCurrConfig2 Unbalance Block
831
Power Loss Alarm
766
Power Supply
728
Programmable Alarm 1
749
Programmable Alarm 10
758
Programmable Alarm 11
759
Programmable Alarm 12
760
Programmable Alarm 13
761
Programmable Alarm 14
762
Programmable Alarm 15
763
Programmable Alarm 16
764
Programmable Alarm 2
750
Programmable Alarm 3
751
Programmable Alarm 4
752
Programmable Alarm 5
753
Programmable Alarm 6
754
BE1-11g
Digital Points