50 - instantaneous overcurrent protection, 50bf - breaker failure protection – Basler Electric BE1-11g User Manual
Page 587
![background image](https://www.manualsdir.com/files/773770/content/doc587.png)
9424200994 Rev N
575
49RTD - Resistance Temperature Device Protection (Optional)
Pickup
Setting Range ........................................................... 0 to 250
°
C (32 to 482
°
F)
Accuracy....................................................................
±2% or ±2
°
C (
±3.6
°
F), whichever is greater
Reset/Pickup Ratio .................................................... 105% / 95%
±1% (over / under) or 5
°
C minimum
Time Delay
Setting Range ........................................................... 0 to 600,000 ms
Accuracy....................................................................
±1 s
50 - Instantaneous Overcurrent Protection
Pickup
5 Ampere CT Setting Range ..................................... 0.5 to 150 A
1 Ampere CT Setting Range ..................................... 0.1 to 30 A
SEF Setting Range ................................................... 0.01 to 7.5 A
Unbalanced Setting Range ....................................... 2 to 100%
Dropout ..................................................................... 93 to 99% of the actual pickup value
3Phase, IA, IB, IC, IG Accuracy
5 Ampere CT .............................................................
±4% or ±50 mA, whichever is greater
1 Ampere CT .............................................................
±4% or ±10 mA, whichever is greater
SEF (Pickup Setting of 0.01 to 4.99 A) .....................
±(5% + 4.5 mA)
SEF (Pickup Setting of 5 to 7.5 A) ............................
±(10% + 4.5 mA)
3I0, I1, I2 Accuracy
5 Ampere CT .............................................................
±3% or ±75 mA, whichever is greater
1 Ampere CT .............................................................
±3% or ±15 mA, whichever is greater
Unbalanced Accuracy
5 Ampere CT .............................................................
±3% of pickup setting
1 Ampere CT .............................................................
±3% of pickup setting
Time Delay
Setting Range ........................................................... 0 to 60,000 ms
Accuracy
Phase & Ground ........................................................
±1% or ±3 cycles, whichever is greater, plus trip time
for instantaneous response (0.0 setting)
*
Residual ....................................................................
±2% or ±3 cycles, whichever is greater, plus trip time
for instantaneous response (0.0 setting)
*
* Trip Time for 0.0 Delay Setting .............................. 1¼ cycles maximum for currents ≥ 5 times the pickup
setting. 1¾ cycles maximum for a current of 2
times pickup. Two cycles maximum for a current
of 1.05 times the pickup setting.
50BF - Breaker Failure Protection
Phase & Ground Pickup
5 Ampere CT Setting Range ..................................... 0.25 to 10 A
1 Ampere CT Setting Range ..................................... 0.05 to 2 A
SEF ........................................................................... 0.01 to 0.5 A
Accuracy
5 Ampere CT .............................................................
±4% or ±50 mA, whichever is greater
1 Ampere CT .............................................................
±4% or ±10 mA, whichever is greater
SEF ...........................................................................
±(5% + 2.5 mA)
BE1-11g
Specifications - 25 Hz Operation