Altera POS-PHY Level 4 IP Core User Manual
Page 88

5–18
Chapter 5: Functional Description—Transmitter
Signals
POS-PHY Level 4 IP Core User Guide
December 2014
Altera Corporation
Table 5–5. Atlantic Transmit Interface (Slave Sink)
(Note 1)
Signal
Direction
Clock
Domain
Description
aN_atxclk
Input
aN_atxclk
Atlantic Clock (one for each Atlantic interface). This input is absent
and internally connected to tdint_clk if a single clock domain is
selected. Signals prefixed with aN_ are synchronous to this clock.
aN_atxdav
Output
Atlantic data available (one for each Atlantic interface). Asserted when
the Atlantic FIFO buffer has at least ctl_atx_fth bytes of free space
available.
aN_atxena
Input
Atlantic enable (one for each Atlantic interface).
aN_atxdat[?:0]
Input
Atlantic data bus (one for each Atlantic interface). The width is set by
the Atlantic interface width parameter.
aN_atxsop
Input
Atlantic start of packet (one for each Atlantic interface).
aN_atxeop
Input
Atlantic end of packet (one for each Atlantic interface).
aN_atxmty[?:0]
Input
Atlantic empty signal (one for each Atlantic interface). Number of
invalid octets on the lower bits of aN_atxdat. Valid only when
aN_atxeop
is asserted, must be zero otherwise. The width is
log2(Atlantic interface width/8)
.
aN_atxerr
Input
Atlantic Error (one for each Atlantic interface). Translates to an EOP-
Abort on the transmit data bus.
aN_atxadr[7:0]
Input
Atlantic port address. Only present when you turn on turn on Shared
Buffer with Embedded Addressing.
Note to
Table 5–5
:
(1) N is equal to the number of ports for the individual buffers mode; N is equal to zero when you turn on Shared Buffer with Embedded
Addressing.