Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 98
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-57
when the drive is running and OFF when the drive is stop; if multi-function output terminal is
set to opposite direction, Relay will be OFF when the drive is running and ON when the drive
is stop.
Bit 1 Bit 0
MO2 MO1
02-24
Reserved
02-25
Desired Frequency Attained 1
Control
mode
VF VFPG
FOCPM
Factory setting: 0
02-26
The Width of the Desired Frequency Attained 1
Control
mode
VF
VFPG
FOCPM
Factory setting: 24
02-27
Desired Frequency Attained 2
Control
mode
VF VFPG
FOCPM
Factory setting: 0
02-28
The Width of the Desired Frequency Attained 2
Control
mode
VF
VFPG
FOCPM
Factory setting: 24
Settings
0.00
~
4800rpm
Once output frequency reaches desired frequency and the corresponding multi-function
output terminal is set to 3 or 4 (Pr.02-11~Pr.02-22), this multi-function output terminal will be
ON.