beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 171

background image

Appendix A Specifications| BLD-E1 Series

A-2

Revision May 2009, 00DE, V0.50

Voltage Class

460V Class

Model

Number

BLD-XXXE1 004 007 015 022 037

Max. Applicable Motor Output (kW)

0.4

0.75

1.5

2.2

3.7

Max.

Applicable

Motor

Output

(hp)

0.5 1.0 2.0 3.0 5.0

Rated

Output

Capacity

(kVA)

1.2 2.0 3.3 4.4 6.8

Rated

Output

Current

(A) 1.5 2.5 4.2 5.5 8.2

Maximum Output Voltage (V)

3-Phase Proportional to Input Voltage

Output Speed (RPM)

1 ~ 4000 RPM

Carrier Frequency (kHz)

2-15

Rated

Input

Current

(A) 1.8 3.2 4.3 7.1 9.0

Rated Voltage/Frequency

3-phase, 380-480V, 50/60Hz

Voltage Tolerance

±

10%(342~528V)

Outp

ut

Rati

ng

Frequency Tolerance

±

5%(47~63Hz)

Cooling Method

Natural Cooling

Fan Cooling

Weight

(kg)

1.2 1.2 1.2 1.7 1.7

General Specifications

Control System

Hall Sensor + 6-step close loop

Speed Setting Resolution

1 RPM

Output Speed Resolution

1 RPM

Torque Characteristics

Including the auto-torque compensation; starting torque can be 150% at

80RPM

Overload Endurance

150% of rated current for 1 minute

Accel/Decel Time

0.1 to 600 seconds (2 Independent settings for Accel/Decel time)

Stall Prevention Level

Setting 20 to 250% of rated current

Co

nt

ro

l Ch

a

ra

ct

erist

ic

s

Regenerated Brake Torque

Approx. 20% (up to 125% possible with optional brake resistor or externally

mounted brake unit

Keypad

Setting by

Speed
Setting

External Signal

Potentiometer-5k

Ω/0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-

function Inputs 3 to 6 (15 steps, up/down)

Keypad

Set by RUN and STOP

Operation

Setting

Signal

External Signal

2 wires/3 wires (MI1, MI2, MI3) and RS-485 serial interface

Multi-function Input Signal

Multi-step selection 0 to 15, accel/decel inhibit, 2 accel/decel switches,
counter, Jog, driver reset, UP/DOWN key settings, ACI/AVI selections,
NPN/PNP input selection

Op

er

at

in

g C

har

ac

te

ris

tic

s

Multi-function Output Indication

AC drive operating, speed attained, zero speed, counter attained indication,
status selections of input terminals, fault indication, overheat alarm and
emergency stop

Protection Functions

Over voltage, over current, under voltage, external fault, motor overload,
ground fault, drive overload and drive overheating