Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 90
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-49
02-01
Multi-Function Input Command 3 (MI3)
Factory Setting: 1
02-02
Multi-Function Input Command 4 (MI4)
Factory Setting: 2
02-03
Multi-Function Input Command 5 (MI5)
Factory Setting: 3
02-04
Multi-Function Input Command 6 (MI6)
Factory Setting: 4
Settings
VF
VFPG
FOCPM
0
:no function
○
○
○
1
:Multi-step command 1
○
○
○
2
:Multi-step command 2
○
○
○
3
:Multi-step command 3
○
○
○
4
:Multi-step command 4
○
○
○
5
:Reset
○
○
○
6
:Reserved
7
:acceleration/deceleration speed inhibit
○
○
○
8
:the 1st, 2nd acceleration/deceleration time
selection
○
○
○
9
:the 3rd, 4th acceleration/deceleration time
selection
○
○
○
10: EF input (Pr.07-28)
○
○
○
11: Reserved
12: Stop output
○
○
○
13~14: Reserved
15
:Running speed command from VR
○
○
○
16
:Running speed command from ACI
○
○
○
17
:Running speed command from AVI
○
○
○
18
:Emergency Stop (Pr.07-28)
○
○
○
19~26
:Reserved
27
:ASR1/ASR2 Selection
○
○
○
28
:Emergency stop (EF1) (Motor coasts to stop)
○
○
○
29~30
:Reserved
31: High torque bias (by Pr.07-21)
○
○
○
32: Middle torque bias (by Pr.07-22)
○
○
○