Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-9
Parameter Explanation
Settings
Factory
Setting
VF VFPG
FOCPM
13~14: Reserved
○
○
○
15
:Running speed
command from VR
○
○
○
16
:Running speed
command from ACI
○
○
○
17
:Running speed
command from AVI
○
○
○
18
:Emergency Stop
(Pr.07-28)
○
○
○
19~26
:Reserved
○
○
○
27
:ASR1/ASR2 Selection
○
○
○
28
:Emergency stop (EF1)
(Motor coasts to stop)
○
○
○
29~30
:Reserved
○
○
○
31: High torque bias (by
Pr.07-21)
○
○
○
32: Middle torque bias (by
Pr.07-22)
○
○
○
33: Low torque bias (by
Pr.07-23)
○
○
○
34-37: Reserved
○
○
○
38: Disable EEPROM write
function
○
○
○
39
:Reserved ○
○
○
40
:Enable drive to
function
○
○
○
02.05 ~
02.08
Reserved
02.09 Digital
Input
Response Time
0.001~ 30.000 Sec
0.005
○
○
○
02.10 Digital
Input
Operation
Direction
0
~65535 0
○
○
○
02.11 Reserved