Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 66
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-25
Parameter
Explanation Settings
Factory
Setting
VF VFPG FOCPM
10.09
Encoder Stall and Slip
Error Treatment
0: Warn and keep operation
1: Warn and decelerate to stop
2: Warn and stop operation
2
○
10.10
Mode Selection for
UVW Input
0: Z signal is at the falling edge
of U-phase
1: Z signal is at the rising edge of
U-phase
0
○
○
10.11
ASR (Auto Speed
Regulation) Control
(P) of Zero Speed
0.0~500.0% 100.0
○
○
○
10.12
ASR (Auto Speed
Regulation) Control (I)
of Zero Speed
0.000~10.000 sec
0.200
○
○
○
10.13
ASR (Auto Speed
Regulation) Control
(P) 1
0.0~500.0% 100.0
○
○
○
10.14
ASR (Auto Speed
Regulation) Control (I)
1
0.000~10.000 sec
0.200
○
○
○
10.15
ASR (Auto Speed
Regulation) Control
(P) 2
0.0~500.0% 100.0
○
○
○
10.16
ASR (Auto Speed
Regulation) Control (I)
2
0.000~10.000 sec
0.200
○
○
○
10.17
ASR 1/ASR2 Switch
Frequency
0~4000RPM (0.00~400.0Hz)
7.00
○
○
○
10.18
ASR Primary Low
Pass Filter Gain
0.000~0.350 sec
0.008
○
○
○
10.19
Zero Speed Gain (P) 0~655.00%
80.00
○
10.20 Zero
Speed/ASR1
0~4000RPM (0.00~400.0Hz)
5.00
○
○