Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-2
Revision May 2009, 00DE, V0.50
4.1 Summary of Parameter Settings
Group 00 System Parameters
: The parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting
VF VFPG FOCPM
00.00
Identity Code of
the Brushless DC
Motor Drive
0
:115V,1PH,0.2KW,1/4HP
2
:115V,1PH,0.4KW,1/2HP
4
:115V,1PH,0.7KW,1HP
0
:230V,1PH,0.2KW,1/4HP
2
:230V,1PH,0.4KW,1/2HP
4
:230V,1PH,0.7KW,1HP
6
:230V,1PH,1.5KW,2HP
8
:230V,1PH,2.2KW,3HP
0
:230V,3PH,0.2KW,1/4HP
2
:230V,3PH,0.4KW,1/2HP
4
:230V,3PH,0.7KW,1HP
6
:230V,3PH,1.5KW,2HP
8
:230V,3PH,2.2KW,3HP
10
:230V,3PH,3.7KW,5HP
3
:460V,3PH,0.4KW,1/2HP
5
:460V,3PH,0.7KW,1HP
7
:460V,3PH,1.5KW,2HP
9
:460V,3PH,2.2KW,3HP
11
:460V,3PH,3.7KW,5HP
Read-
only
○
○
○
00.01 Rated
Current
Display of the
Brushless DC
Motor Drive
Display according to the model
series
Read-
only
○
○
○
00.02 Parameter
Reset
0
:No function
10
:All parameters are reset to
factory settings
0
○
○
○
00.03 Start-up
Display
Selection
0
:Frequency command
1
:Out put frequency
2
:DC BUS voltage
3
:Output current
4
:output voltage
0
○
○
○