Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-60

Revision May 2009, 00DE, V0.50

03-07

Positive/negative Bias Mode (ACI) (can be set to 0 or 1 only)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

03-08

Positive/negative Bias Mode (AVI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings

0

Zero

bias

1

Serve bias as the center, lower than bias=bias

2

Serve bias as the center, greater than bias=bias

3

The absolute value of the bias voltage while serving as the center
(unipolar)

4

Serve bias as the center (unipolar)

In a noisy environment, it is advantageous to use negative bias to provide a noise margin. It is

recommended NOT to use less than 1V to set the operating frequency.

10V

5

1 2 3 4

-1

-2

-3

-4

-5

-10 V

6 7 8 9

03-00

to

03-02

-6

-7

-8

-9

0

1

2

3

4

4

2

2

4

2

03-09~03-11 gain is positive

4

Z er o bias

Serv e bias as the center, lower than bias = bias

Serv e bias as the center, gr eater than bias=bias

T he absolute value of the bias v oltage
while s er ving as the c enter (unipolar)

Serv e bias as the center (unipolar)

bias

bias

Positiv e bias

Negativ e bias

03-09

Analog Input Gain 1 (VR)

Control

mode

VF

VFPG

FOCPM

Factory setting: 100.0

03-10

Analog Input Gain 1 (ACI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 100.0

03-11

Analog Input Gain 1 (AVI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 100.0

Settings

0.0~500.0%

Parameters 03-03 to 03-11 are used when the source of frequency command is the analog

voltage/current signal.