beautypg.com

2 ground fault, 3 over voltage (ov) – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 149

background image

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

5-2

Revision May 2009, 00DE, V0.50

5.2 Ground Fault

GFF

Ground faul t

No

Yes

Is output circuit(c able or
motor) of brushles s DC
motor drive grounded?

Remove ground fault

Maybe B rushless DC motor
driv e has malfunc tion or
misoperation due to noise.
Please contac t DELTA.

5.3 Over Voltage (OV)

Ov er v oltage

Yes

No

Yes

No

No

No

Is voltage within
specific ation

Has ov er -v ol tage oc curr ed without load

Maybe br ushless DC
motor dr ive has

malfunction or
misoperation due to

noise. Pl eas e contact
DELTA.

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

When O V oc curs, check if the
voltage of DC B US is greater

than protection v al ue

Dose O V oc cur when
sudden acc eleration

stops

Increase
deceleration

time

Increase
acceler ati on

time

Reduc e moment of load inertia

Use br ake unit or DC br ak e

Need to check control method. Please c ontact DELTA.

Need to consi der usi ng
brake unit or

DC brake

Reduc e moment
of inertia

Reduc e voltage to
be within s pec .

Increase setti ng time