beautypg.com

Group 07 protection parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 61

background image

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-20

Revision May 2009, 00DE, V0.50

Group 07 Protection Parameters

: The parameter can be set during operation.

Parameter

Explanation Settings

Factory

Setting

VF VFPG FOCPM

07.00 Reserved

07.01 Reserved

07.02 DC

Brake

Current Level

0~100% 0

07.03 DC

Brake

Time

during Start-up

0.0~60.0 sec

0.0

07.04 DC

Brake

Time

during Stopping

0.0~60.0 sec

0.0

07.05 DC

Brake

Starting

Frequency

0~4000rpm (0.00~400.0Hz)

0.00

07.06 DC

Brake

Proportional Gain

1~500 50

07.07 ~

07.10

Reserved

07.11

Fan Control

0: Fan always ON

1: 1 minute after brushless DC motor

drive stops, fan will be OFF

2: Brushless DC motor drive runs

and fan ON, brushless DC motor

drive stops and fan OFF

3: Fan ON to run when preliminary

heat sink temperature attained

4: Fan OFF

1

07.12 Reserved

07.13 Reserved

07.14 Maximum

Torque

Command

0

~300% 100

07.15 ~

07.18

Reserved