Group 10: speed feedback control parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 65
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-24
Revision May 2009, 00DE, V0.50
Group 10: Speed Feedback Control Parameters
: The parameter can be set during operation.
Parameter
Explanation Settings
Factory
Setting
VF VFPG FOCPM
10.00 Encoder
Type
0
:No function
1
:ABZ
2
:ABZ+UVW
3
:AB+PWM
3
○
○
10.01 Encoder
Pulse 1~25000
256
○
○
10.02 Encoder
Input
Type
Setting
0
:Disable
0: Disable
1: Phase A leads in a forward run
command and phase B leads in
a reverse run command
2: Phase B leads in a forward
run command and phase A leads
in a reverse run command
3
:Phase A is a pulse input and
phase B is a direction input.
(L=reverse direction, H=forward
direction)
1
○
○
10.03 Encoder
Feedback
Fault Treatment
(PGF1, PGF2)
0: Warn and keep operation
1: Warn and decelerate to stop
2: Warn and stop operation
2
○
10.04 Detection
Time
for
Encoder Feedback
Fault
0.0~10.0 sec
3.0
○
○
10.05 Encoder
Stall
Level
(PGF3)
0~120% (0
:disable) 115
○
○
10.06 Encoder
Stall
Detection Time
0.0
~2.0 sec
0.1
○
○
10.07
Encoder Slip Range
(PGF4)
0~50% (0
:disable) 50
○
○
10.08 Encoder
Slip
Detection Time
0.0
~10.0 sec
0.5
○
○