beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 92

background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-51

Settings

Functions

Descriptions

8

The 1

st

, 2

nd

acceleration

or deceleration time
selection

9

The 3

rd

, 4

th

acceleration

or deceleration time
selection

The acceleration/deceleration time of the drive could
be selected from this function or the digital statuses of
the terminals; there are 4 acceleration/deceleration
speeds in total for selection.

Bit 0

Bit

1

Descriptions

0 0

First

acceleration/deceleration

time

When output frequency is less

than Pr.01-23 (Switch

Frequency between 1st/4th

Accel/decel), it will output 4

th

accel/decel time.

0 1

2

nd

accel./decel. time

1 0

3

rd

accel./decel. time

1 1

4

th

accel./decel. time

If the drive receives STOP command, it will decelerate
to stop by Pr.01-31.

10 EF

Input

External fault input terminal and decelerates by Pr.07-
28. (EF fault will be recorded)

11 Reserved

12 Stop

output

When this function is enabled, the drive output will stop
immediately and the motor is free run. When this
function is disabled, the drive will accelerate to the
frequency setting.

13-14 Reserved

15

Operation speed
command form VR

When the source of operation speed command is set to
VR, ACI and AVI at the same time and two or above
terminals are ON, the priority is VR>ACI>AVI.
When this function is enabled, the source of the
frequency will force to be VR.

16

Operation speed
command form ACI

When this function is enabled, the source of the
frequency will force to be ACI.

17

Operation speed
command form AVI

When this function is enabled, the source of the
frequency will force to be AVI.

18 Emergency

Stop

When this function is enabled, the drive will ramp to stop
by Pr.07-28 setting.

19-26 Reserved